<?xml version="1.0" encoding="utf-8" ?><rss version="2.0"
     xmlns:atom="http://www.w3.org/2005/Atom"
     xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
     xmlns:media="http://search.yahoo.com/mrss/">

   <channel>
       <title>HbA1c - ÖQUASTA</title>
       <description><![CDATA[]]></description>
       <link>https://oequasta.at/de/publikationen/hba1c?format=html</link>
              <lastBuildDate>Wed, 15 Feb 2017 16:35:37 +0100</lastBuildDate>
       <atom:link href="https://oequasta.at/de/publikationen/hba1c?format=rss" rel="self" type="application/rss+xml"/>
       <language>de-DE</language>
       <sy:updatePeriod>hourly</sy:updatePeriod>
       <sy:updateFrequency>1</sy:updateFrequency>

              <item>
           <title>Global standardization of glycated hemoglobin measurement</title>
           <link>https://oequasta.at/de/publikationen/hba1c/14-global-standardization-of-glycated-hemoglobin-measurement?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/14-global-standardization-of-glycated-hemoglobin-measurement/file" length="71139" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/14-global-standardization-of-glycated-hemoglobin-measurement/file"
                fileSize="71139"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">Global standardization of glycated hemoglobin measurement</media:title>
           <media:description type="html"><![CDATA[<p>The measurement of glycated hemoglobin is central in the monitoring of glycemic control in patients with diabetes. There are at least 30 different laboratory assays commercially available to measure the proportion of HbA<sub>1c</sub> in blood. In 1995 the IFCC established a Working Group (IFCC WG-HbA<sub>1c</sub>) to achieve international standardization of HbA<sub>1c</sub> measurement. The main achievements can be summarized as follows: a) a reference measurement procedure has been established with purified primary calibrators; b) a network of reference laboratories has been developed worldwide; and c) work has begun on implementation of traceability to the IFCC reference system. The IFCC WG-HbA<sub>1c</sub> recognizes the recommendation of the IFCC-IUPAC Committee on Nomenclature, Properties and Units that the analyte measured by the IFCC reference measurement procedure has been defined as Î²N1-deoxyfructosylhemoglobin and that the recommended measurement units are mmol/mol. The IFCC WG-HbA<sub>1c</sub> recommends maintaining the use of the name HbA<sub>1c</sub> in clinical practice.</p>
<p>Clin Chem Lab Med 2007;45:1077â€“80.</p>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/14-global-standardization-of-glycated-hemoglobin-measurement?format=html</guid>
           <description><![CDATA[<p>The measurement of glycated hemoglobin is central in the monitoring of glycemic control in patients with diabetes. There are at least 30 different laboratory assays commercially available to measure the proportion of HbA<sub>1c</sub> in blood. In 1995 the IFCC established a Working Group (IFCC WG-HbA<sub>1c</sub>) to achieve international standardization of HbA<sub>1c</sub> measurement. The main achievements can be summarized as follows: a) a reference measurement procedure has been established with purified primary calibrators; b) a network of reference laboratories has been developed worldwide; and c) work has begun on implementation of traceability to the IFCC reference system. The IFCC WG-HbA<sub>1c</sub> recognizes the recommendation of the IFCC-IUPAC Committee on Nomenclature, Properties and Units that the analyte measured by the IFCC reference measurement procedure has been defined as Î²N1-deoxyfructosylhemoglobin and that the recommended measurement units are mmol/mol. The IFCC WG-HbA<sub>1c</sub> recommends maintaining the use of the name HbA<sub>1c</sub> in clinical practice.</p>
<p>Clin Chem Lab Med 2007;45:1077â€“80.</p>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:35:37 +0100</pubDate>
       </item>
              <item>
           <title>Standardisation History Science and Politics</title>
           <link>https://oequasta.at/de/publikationen/hba1c/13-standardisation-history-science-and-politics?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/13-standardisation-history-science-and-politics/file" length="291884" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/13-standardisation-history-science-and-politics/file"
                fileSize="291884"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">Standardisation History Science and Politics</media:title>
           <media:description type="html"><![CDATA[<p>Significant analytical improvements have occurred since glycated haemoglobin (GHb), measured as total HbA<sub>1</sub>, was first used in routine clinical laboratories around 1977. Following the publication of the Diabetes Control and Complications Trial (DCCT) study in 1993 the issue of international standardisation became an important objective for scientists and clinicians. The lack of international standardisation led several countries to develop national standardisation programs. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Working Group on Standardisation of HbA<sub>1c</sub> established a true international reference measurement system for HbA<sub>1c</sub> and the successful preparation of pure HbA<sub>1c</sub> calibration material that should lead to further improvements in inter-method and inter-laboratory variability. Reporting of HbA<sub>1c</sub> has been agreed using the units of mmol/mol (IFCC) and percent (National Glycohemoglobin Standardization Program, NGSP).</p>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/13-standardisation-history-science-and-politics?format=html</guid>
           <description><![CDATA[<p>Significant analytical improvements have occurred since glycated haemoglobin (GHb), measured as total HbA<sub>1</sub>, was first used in routine clinical laboratories around 1977. Following the publication of the Diabetes Control and Complications Trial (DCCT) study in 1993 the issue of international standardisation became an important objective for scientists and clinicians. The lack of international standardisation led several countries to develop national standardisation programs. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Working Group on Standardisation of HbA<sub>1c</sub> established a true international reference measurement system for HbA<sub>1c</sub> and the successful preparation of pure HbA<sub>1c</sub> calibration material that should lead to further improvements in inter-method and inter-laboratory variability. Reporting of HbA<sub>1c</sub> has been agreed using the units of mmol/mol (IFCC) and percent (National Glycohemoglobin Standardization Program, NGSP).</p>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:35:33 +0100</pubDate>
       </item>
              <item>
           <title>Statistcal Methods for Monitoring the Relationship between the IFCC Reference Measurement</title>
           <link>https://oequasta.at/de/publikationen/hba1c/12-statistcal-methods-for-monitoring-the-relationship-between-the-ifcc-reference-measurementpdf?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/12-statistcal-methods-for-monitoring-the-relationship-between-the-ifcc-reference-measurementpdf/file" length="225196" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/12-statistcal-methods-for-monitoring-the-relationship-between-the-ifcc-reference-measurementpdf/file"
                fileSize="225196"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">Statistcal Methods for Monitoring the Relationship between the IFCC Reference Measurement</media:title>
           <media:description type="html"><![CDATA[<p>Statistical Methods for Monitoring the Relationship between the IFCC Reference Measurement Procedure for Hemoglobin A<sub>1c</sub> and the Designated Comparison Methods in the United States, Japan, and Sweden.</p>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/12-statistcal-methods-for-monitoring-the-relationship-between-the-ifcc-reference-measurementpdf?format=html</guid>
           <description><![CDATA[<p>Statistical Methods for Monitoring the Relationship between the IFCC Reference Measurement Procedure for Hemoglobin A<sub>1c</sub> and the Designated Comparison Methods in the United States, Japan, and Sweden.</p>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:35:29 +0100</pubDate>
       </item>
              <item>
           <title>Consensus statement on the worldwide standardisation of the HbA1c measurement</title>
           <link>https://oequasta.at/de/publikationen/hba1c/11-consensus-statement-on-the-worldwide-standardisation-of-the-hba1c-measurement?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/11-consensus-statement-on-the-worldwide-standardisation-of-the-hba1c-measurement/file" length="67512" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/11-consensus-statement-on-the-worldwide-standardisation-of-the-hba1c-measurement/file"
                fileSize="67512"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">Consensus statement on the worldwide standardisation of the HbA1c measurement</media:title>
           <media:description type="html"><![CDATA[<p>The HbA<sub>1c</sub> assay has become the gold-standard measurement of chronic glycaemia for over two decades. Anchored in the knowledge that elevated HbA<sub>1c</sub> values increase the likelihood of the microvascular complications of diabetes (and perhaps macrovascular complications as well), clinicians have used the HbA<sub>1c</sub> test results to guide treatment decisions, and the assay has become the cornerstone for the assessment of diabetes care.</p>
<p>The clinical world has assumed that the HbA1c assay reflects average glycaemia over the preceding few months.</p>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/11-consensus-statement-on-the-worldwide-standardisation-of-the-hba1c-measurement?format=html</guid>
           <description><![CDATA[<p>The HbA<sub>1c</sub> assay has become the gold-standard measurement of chronic glycaemia for over two decades. Anchored in the knowledge that elevated HbA<sub>1c</sub> values increase the likelihood of the microvascular complications of diabetes (and perhaps macrovascular complications as well), clinicians have used the HbA<sub>1c</sub> test results to guide treatment decisions, and the assay has become the cornerstone for the assessment of diabetes care.</p>
<p>The clinical world has assumed that the HbA1c assay reflects average glycaemia over the preceding few months.</p>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:35:27 +0100</pubDate>
       </item>
              <item>
           <title>IFCC Reference System for Measurement of Hemoglobin A1c in Human Blood</title>
           <link>https://oequasta.at/de/publikationen/hba1c/10-ifcc-reference-system-for-measurement-of-hemoglobin-a1c-in-human-blood?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/10-ifcc-reference-system-for-measurement-of-hemoglobin-a1c-in-human-blood/file" length="187908" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/10-ifcc-reference-system-for-measurement-of-hemoglobin-a1c-in-human-blood/file"
                fileSize="187908"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">IFCC Reference System for Measurement of Hemoglobin A1c in Human Blood</media:title>
           <media:description type="html"><![CDATA[<p>IFCC Reference System for Measurement of Hemoglobin A<sub>1c</sub> in Human Blood and the National Standardization Schemes in the United States, Japan, and Sweden: A Method-Comparison Study</p>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/10-ifcc-reference-system-for-measurement-of-hemoglobin-a1c-in-human-blood?format=html</guid>
           <description><![CDATA[<p>IFCC Reference System for Measurement of Hemoglobin A<sub>1c</sub> in Human Blood and the National Standardization Schemes in the United States, Japan, and Sweden: A Method-Comparison Study</p>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:35:24 +0100</pubDate>
       </item>
              <item>
           <title>Candidate reference methods for hemoglobin A1c based on peptide mapping</title>
           <link>https://oequasta.at/de/publikationen/hba1c/9-candidate-reference-methods-for-hemoglobin-a1c-based-on-peptide-mapping?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/9-candidate-reference-methods-for-hemoglobin-a1c-based-on-peptide-mapping/file" length="204709" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/9-candidate-reference-methods-for-hemoglobin-a1c-based-on-peptide-mapping/file"
                fileSize="204709"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">Candidate reference methods for hemoglobin A1c based on peptide mapping</media:title>
           <media:description type="html"><![CDATA[<p>A reference method that specifically measures hemoglobin (Hb) A<sub>1c</sub> is an essential part of the reference system for the international standardization of Hb A<sub>1c</sub>/glycohemoglobin. We have developed a new method for quantification, based on the specific N-terminal residue of the hemoglobin <em>Î²</em>-chains. Enzymatic cleavage of the intact hemoglobin molecule with endoproteinase Glu-C has been optimized to obtain the b-N-terminal hexapeptides of Hb A<sub>1c</sub> and Hb A<sub>0</sub>. These peptides have been separated by reversed-phase HPLC and quantitated by electrospray ionization-mass spectrometry (method A) or by capillary electrophoresis (method B). With these peptides and hyphenated separation techniques, it has been possible to overcome the insufficient resolution of currently used protein separation systems for Hb A<sub>1c</sub>.</p>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/9-candidate-reference-methods-for-hemoglobin-a1c-based-on-peptide-mapping?format=html</guid>
           <description><![CDATA[<p>A reference method that specifically measures hemoglobin (Hb) A<sub>1c</sub> is an essential part of the reference system for the international standardization of Hb A<sub>1c</sub>/glycohemoglobin. We have developed a new method for quantification, based on the specific N-terminal residue of the hemoglobin <em>Î²</em>-chains. Enzymatic cleavage of the intact hemoglobin molecule with endoproteinase Glu-C has been optimized to obtain the b-N-terminal hexapeptides of Hb A<sub>1c</sub> and Hb A<sub>0</sub>. These peptides have been separated by reversed-phase HPLC and quantitated by electrospray ionization-mass spectrometry (method A) or by capillary electrophoresis (method B). With these peptides and hyphenated separation techniques, it has been possible to overcome the insufficient resolution of currently used protein separation systems for Hb A<sub>1c</sub>.</p>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:35:21 +0100</pubDate>
       </item>
              <item>
           <title>Standardised advice</title>
           <link>https://oequasta.at/de/publikationen/hba1c/8-standardised-advice?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/8-standardised-advice/file" length="33504" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/8-standardised-advice/file"
                fileSize="33504"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">Standardised advice</media:title>
           <media:description type="html"><![CDATA[<p>Relating to the Implementation of the IFCC, ADA, EASD and IDF Consensus Statement of on reporting of HbA<sub>1c</sub></p>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/8-standardised-advice?format=html</guid>
           <description><![CDATA[<p>Relating to the Implementation of the IFCC, ADA, EASD and IDF Consensus Statement of on reporting of HbA<sub>1c</sub></p>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:35:16 +0100</pubDate>
       </item>
              <item>
           <title>Recommendation for term and measurement unit for HbA1c (iFCC)</title>
           <link>https://oequasta.at/de/publikationen/hba1c/7-recommendation-for-term-and-measurement-unit-for-hba1c-ifcc?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/7-recommendation-for-term-and-measurement-unit-for-hba1c-ifcc/file" length="696412" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/7-recommendation-for-term-and-measurement-unit-for-hba1c-ifcc/file"
                fileSize="696412"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">Recommendation for term and measurement unit for HbA1c (iFCC)</media:title>
           <media:description type="html"><![CDATA[<p>The IFCC has recently approved a reference measurment procedure for measuring the propertf often designated "HbA1c". This analytially specific procedure involving single molecular species allows calculation of measurement results as "amount-of-substance fraction" rather than mass fraction. In addition it provides well-defined metrological traceability to the International System of Units (SI).</p>
<p>As the numerical values of the measurement results will change with the new measurement proceddure, it is timely to reconsider the current termsfor the property in terms of system, component, and kind-of-property, as well as the expression of the measurement result.</p>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/7-recommendation-for-term-and-measurement-unit-for-hba1c-ifcc?format=html</guid>
           <description><![CDATA[<p>The IFCC has recently approved a reference measurment procedure for measuring the propertf often designated "HbA1c". This analytially specific procedure involving single molecular species allows calculation of measurement results as "amount-of-substance fraction" rather than mass fraction. In addition it provides well-defined metrological traceability to the International System of Units (SI).</p>
<p>As the numerical values of the measurement results will change with the new measurement proceddure, it is timely to reconsider the current termsfor the property in terms of system, component, and kind-of-property, as well as the expression of the measurement result.</p>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:35:13 +0100</pubDate>
       </item>
              <item>
           <title>Global standardization of glycated hemoglobin measurement the position of the IFCC Working Group</title>
           <link>https://oequasta.at/de/publikationen/hba1c/6-global-standardization-of-glycated-hemoglobin-measurement-the-position-of-the-ifcc-working-group?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/6-global-standardization-of-glycated-hemoglobin-measurement-the-position-of-the-ifcc-working-group/file" length="1390547" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/6-global-standardization-of-glycated-hemoglobin-measurement-the-position-of-the-ifcc-working-group/file"
                fileSize="1390547"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">Global standardization of glycated hemoglobin measurement the position of the IFCC Working Group</media:title>
           <media:description type="html"><![CDATA[<p>The measurement of glycated hemoglobin is central in the monitoring of glycemic control in patients with diabetes. There are at least 30 different laboratory assays commercially available to measure the proportion of HbA<sub>1c</sub> in blood. In 1995 the IFCC established a Working Group (IFCC WG-HbA<sub>1c</sub>) to achieve international standardization of HbA<sub>1c</sub> measurement. The main achievements can be summarized as follows: a) a reference measurement procedure has been established with purified primary calibrators; b) a network of reference laboratories has been developed worldwide; and c) work has begun on implementation of traceability to the IFCC reference system. The IFCC WG-HbA<sub>1c</sub> recognizes the recommendation of the IFCC-IUPAC Committee on Nomenclature, Properties and Units that the analyte measured by the IFCC reference measurement procedure has been defined as Î²N1-deoxyfructosylhemoglobin and that the recommended measurement units are mmol/mol. The IFCC WG-HbA<sub>1c</sub> recommends maintaining the use of the name HbA<sub>1c</sub> in clinical practice.</p>
<p>Clin Chem Lab Med 2007;45:1077â€“80.</p>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/6-global-standardization-of-glycated-hemoglobin-measurement-the-position-of-the-ifcc-working-group?format=html</guid>
           <description><![CDATA[<p>The measurement of glycated hemoglobin is central in the monitoring of glycemic control in patients with diabetes. There are at least 30 different laboratory assays commercially available to measure the proportion of HbA<sub>1c</sub> in blood. In 1995 the IFCC established a Working Group (IFCC WG-HbA<sub>1c</sub>) to achieve international standardization of HbA<sub>1c</sub> measurement. The main achievements can be summarized as follows: a) a reference measurement procedure has been established with purified primary calibrators; b) a network of reference laboratories has been developed worldwide; and c) work has begun on implementation of traceability to the IFCC reference system. The IFCC WG-HbA<sub>1c</sub> recognizes the recommendation of the IFCC-IUPAC Committee on Nomenclature, Properties and Units that the analyte measured by the IFCC reference measurement procedure has been defined as Î²N1-deoxyfructosylhemoglobin and that the recommended measurement units are mmol/mol. The IFCC WG-HbA<sub>1c</sub> recommends maintaining the use of the name HbA<sub>1c</sub> in clinical practice.</p>
<p>Clin Chem Lab Med 2007;45:1077â€“80.</p>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:35:09 +0100</pubDate>
       </item>
              <item>
           <title>Implementation of hemoglobin A1c results traceable to the IFCC reference system</title>
           <link>https://oequasta.at/de/publikationen/hba1c/5-implementation-of-hemoglobin-a1c-results-traceable-to-the-ifcc-reference-system?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/5-implementation-of-hemoglobin-a1c-results-traceable-to-the-ifcc-reference-system/file" length="1000570" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/5-implementation-of-hemoglobin-a1c-results-traceable-to-the-ifcc-reference-system/file"
                fileSize="1000570"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">Implementation of hemoglobin A1c results traceable to the IFCC reference system</media:title>
           <media:description type="html"><![CDATA[<p>Implementation of hemoglobin A<sub>1c</sub> results traceable to the IFCC reference system: the way Forward</p>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/5-implementation-of-hemoglobin-a1c-results-traceable-to-the-ifcc-reference-system?format=html</guid>
           <description><![CDATA[<p>Implementation of hemoglobin A<sub>1c</sub> results traceable to the IFCC reference system: the way Forward</p>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:35:05 +0100</pubDate>
       </item>
              <item>
           <title>American Diabetes Association (ADA)</title>
           <link>https://oequasta.at/de/publikationen/hba1c/4-american-diabetes-association-ada?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/4-american-diabetes-association-ada/file" length="672387" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/4-american-diabetes-association-ada/file"
                fileSize="672387"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">American Diabetes Association (ADA)</media:title>
           <media:description type="html"><![CDATA[<p>American Diabetes Association (ADA), European Association for the Study of Diabetes (EASD), International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and International Diabetes Federation (IDF) consensus statement on the worldwide standardization of the hemoglobin A1c measurement</p>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/4-american-diabetes-association-ada?format=html</guid>
           <description><![CDATA[<p>American Diabetes Association (ADA), European Association for the Study of Diabetes (EASD), International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and International Diabetes Federation (IDF) consensus statement on the worldwide standardization of the hemoglobin A1c measurement</p>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:35:03 +0100</pubDate>
       </item>
              <item>
           <title>Diabetes Forum 2010</title>
           <link>https://oequasta.at/de/publikationen/hba1c/3-diabetes-forum-2010?format=html</link>
           <enclosure url="https://oequasta.at/de/publikationen/hba1c/3-diabetes-forum-2010/file" length="10199808" type="application/pdf" />
           <media:content
                url="https://oequasta.at/de/publikationen/hba1c/3-diabetes-forum-2010/file"
                fileSize="10199808"
                type="application/pdf"
                medium="document"
           />
           <media:title type="plain">Diabetes Forum 2010</media:title>
           <media:description type="html"><![CDATA[<ul>
<li>Beurteilung der GlykÃ¤miekontrolle in Umbruch</li>
<li>Vom Analyseartefakt zum Goldstandard der Diabeteskontrolle</li>
<li>Weltweite HbA1c â€“Standardisierung nach IFCC Fakten und HintergrÃ¼nde</li>
<li>Labors messen weiter wie gewohnt</li>
<li>Beurteilung der Stoffwechselkontrolle HbA<sub>1c</sub> ist nicht alles</li>
<li>HbA<sub>1c</sub> als Kriterium fÃ¼r die Diabetesdiagnose</li>
<li>Probleme der HbA<sub>1c</sub> â€“Bestimmung bei Nierenversagen</li>
</ul>]]></media:description>
                      <guid isPermaLink="true">https://oequasta.at/de/publikationen/hba1c/3-diabetes-forum-2010?format=html</guid>
           <description><![CDATA[<ul>
<li>Beurteilung der GlykÃ¤miekontrolle in Umbruch</li>
<li>Vom Analyseartefakt zum Goldstandard der Diabeteskontrolle</li>
<li>Weltweite HbA1c â€“Standardisierung nach IFCC Fakten und HintergrÃ¼nde</li>
<li>Labors messen weiter wie gewohnt</li>
<li>Beurteilung der Stoffwechselkontrolle HbA<sub>1c</sub> ist nicht alles</li>
<li>HbA<sub>1c</sub> als Kriterium fÃ¼r die Diabetesdiagnose</li>
<li>Probleme der HbA<sub>1c</sub> â€“Bestimmung bei Nierenversagen</li>
</ul>]]></description>
           <author>office@webkonzepte.at (Super User)</author>
           <category>HbA1c</category>
           <pubDate>Wed, 15 Feb 2017 16:34:58 +0100</pubDate>
       </item>
          </channel>
</rss>